SKU:

LC1D09B7TQ

Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 9A, 24VAC 50/60Hz coil, bulk qty

$69.20
Contactor, TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 9A, 24VAC 50/60Hz coil, bulk qty
  • New modern look & feel of all machines
  • Designed to meet the requirements of Electro domestic and HVAC applications
  • Easier to install and operate with multi-standard screws
  • With IEC60335-1 compliance, improved fire resistance, and dustproof auxiliaries
  • Digital customer experience for technical documents
  • Maintenance guide via EcoStruxureTM Facility Expect
Manufacturer: Schneider Electric
Estimated Delivery Date: 26-Sep-2024
TeSys D contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3/3e (4kW@400V). It provides a 24V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Pack of 10 units. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Products specifications

Attribute nameAttribute value
Main
[Ie] rated operational current9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit, 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit, 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
Utilisation categoryAC-3e, AC-1, AC-3
[Uc] control circuit voltage24 V AC 50/60 Hz
Device short nameLC1D
RangeTeSys Deca, TeSys
Range of productTeSys Deca
Poles description3P
Product or component typecontactor
Contactor applicationresistive load, motor control
[Ue] rated operational voltagepower circuit: <= 690 V AC 25...400 Hz
Complementary
Compatibility codeLC1D
Associated fuse rating25 A at <= 690 V coordination type 1 for power circuit, 20 A at <= 690 V coordination type 2 for power circuit, 10 A gG for control circuit conforming to IEC 60947-5-1
Control circuit typeAC at 50/60 Hz
Protective coverwith
[Ui] rated insulation voltagepower circuit: 690 V conforming to IEC 60947-4-1, control circuit: 690 V conforming to IEC 60947-4-1, power circuit: 600 V UL certified, power circuit: 600 V CSA certified, control circuit: 600 V UL certified, control circuit: 600 V CSA certified
Overvoltage categoryIII
Coil technologywithout built-in bidirectional peak limiting diode suppressor
Inrush power in VA70-70 VA cos phi 0.75 (at 20 °C)
Auxiliary contact composition1 NO + 1 NC
Average impedance2.5 mOhm - Ith 25 A 50 Hz for power circuit
Power dissipation per pole0.2 W AC-3e, 1.56 W AC-1, 0.2 W AC-3
Minimum switching current5 mA for control circuit
Non-overlap time1.5 ms on energisation between NC and NO contacts, 1.5 ms on de-energisation between NC and NO contacts
Heat dissipation2-3 W at 50/60 Hz for control circuit
Mechanical durability15000000 cycles
Tightening torquepower circuit: 1.7 N.m - with screwdriver pozidriv No 2, control circuit: 1.7 N.m - with screwdriver pozidriv No 2, power circuit: 1.7 N.m - with screwdriver Philips No 2, power circuit: 1.7 N.m - with screwdriver flat Ø 6 mm, control circuit: 1.7 N.m - with screwdriver Philips No 2, control circuit: 1.7 N.m - with screwdriver flat Ø 6 mm
Minimum switching voltage17 V for control circuit
Operating time12...22 ms closing, 4...19 ms opening
Irms rated making capacity250 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for control circuit conforming to IEC 60947-5-1
Rated breaking capacity250 kA at 440 V for power circuit conforming to IEC 60947
Safety reliability levelB10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1, B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
Control circuit voltage limits0.85...1.1 Uc (60-60 °C):operational AC 60 Hz, 0.8...1.1 Uc (60-60 °C):operational AC 50 Hz, 0.3...0.6 Uc (60-60 °C):drop-out AC 50/60 Hz
[Ith] conventional free air thermal current25 A (at 60 °C) for power circuit, 10 A (at 60 °C) for control circuit
Motor power hp2 hp at 200/208 V AC 50/60 Hz for 3 phases motors conforming to UL, 7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors conforming to UL, 7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors conforming to CSA, 5 hp at 460/480 V AC 50/60 Hz for 3 phases motors conforming to UL, 5 hp at 460/480 V AC 50/60 Hz for 3 phases motors conforming to CSA, 2 hp at 230/240 V AC 50/60 Hz for 3 phases motors conforming to UL, 2 hp at 230/240 V AC 50/60 Hz for 3 phases motors conforming to CSA, 2 hp at 200/208 V AC 50/60 Hz for 3 phases motors conforming to CSA, 1 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to UL, 1 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to CSA, 0.5 hp at 115 V AC 60 Hz for 1 phase motors conforming to UL, 0.5 hp at 115 V AC 60 Hz for 1 phase motors conforming to CSA
Motor power kW2.2 kW at 400 V AC (AC-4), 2.2 kW at 220...230 V AC 50/60 Hz, 4 kW at 415...440 V AC 50/60 Hz, 5.5 kW at 660...690 V AC 50/60 Hz, 5.5 kW at 500 V AC 50/60 Hz, 4 kW at 380...400 V AC 50/60 Hz
Hold-in power consumption in VA7-7 VA 50/60 Hz cos phi 0.3 (at 20 °C)
Maximum operating rate3600 cyc/h 60 °C
Connections - terminalspower circuit: screw clamp terminal 2 1-2.5 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminal 1 1-4 mm² - cable stiffness: flexible with cable end, power circuit: screw clamp terminal 2 1-4 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminal 1 1-4 mm² - cable stiffness: flexible without cable end, power circuit: screw clamp terminal 2 1-4 mm² - cable stiffness: solid without cable end, power circuit: screw clamp terminal 1 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminal 2 1-2.5 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminal 1 1-4 mm² - cable stiffness: flexible with cable end, control circuit: screw clamp terminal 1 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminal 2 1-4 mm² - cable stiffness: solid without cable end, control circuit: screw clamp terminal 2 1-4 mm² - cable stiffness: flexible without cable end, control circuit: screw clamp terminal 1 1-4 mm² - cable stiffness: solid without cable end
Pole contact composition3 NO
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Insulation resistance> 10 MOhm for control circuit
Mounting supportrail, plate
Environment
Fire resistance850 °C conforming to IEC 60695-2-1
Quantity per setset of 10
Mechanical robustnessvibrations contactor closed (4 Gn, 5...300 Hz) , vibrations contactor opened (2 Gn, 5...300 Hz) , shocks contactor closed (15 Gn for 11 ms) , shocks contactor opened (10 Gn for 11 ms)
Climatic withstandconforming to IEC 60947-1 Annex Q category D exposure to damp heat,  conforming to IACS E10 exposure to damp heat
StandardsIEC 60335-1, EN/IEC 60947-5-1, CSA C22.2 No 14, UL 508, EN/IEC 60947-4-1
Height77 mm
Permissible ambient air temperature around the device-40-70 °C at Uc, -5-60 °C
Operating altitude3000 m without derating
Net weight3.2 kg
Product certificationsUKCA, RINA, GL, GOST, CCC, LROS (Lloyds register of shipping), CSA, BV, DNV, UL
IP degree of protectionIP2X conforming to VDE 0106, IP2X conforming to IEC 60529
Depth86 mm
Width45 mm
Flame retardanceV1 conforming to UL 94
Packing Units
Unit Type of Package 11
Number of Units in Package 11
Package 1 Height4.700 cm
Package 1 Width7.400 cm
Package 1 Length8.800 cm
Package 1 Weight334.000 g
Unit Type of Package 22
Number of Units in Package 224
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight8.586 kg